Air conditioning systems with expansion valve
Troubleshooting Procedures
parti 1
Low pressure:
Possible causes:
Troubleshooting Procedures
parti 1
Correct evaluation of the pressure manometer display is particularly important. Here are some examples:
1-
Low pressure:
hoch
High pressure:
high
Outflow temperature at the centre vent:
higher, up to
ambient temperature
ambient temperature
Possible causes:
engine overheated, condenser
contaminated, condenser fan
defective-incorrect direction of
rotation, system overfilled
contaminated, condenser fan
defective-incorrect direction of
rotation, system overfilled
2-
Low pressure:
normal to occasionally low
High pressure:
high, occasionally
Outflow temperature at the centre vent:
higher, possibly fluctuating
Possible causes:
expansion valve stuck, occasionally
closedzXDF
closedzXDF
3-
Low pressure:
normal
">
High pressure:
high
Outflow temperature at the centre vent:
slightly higher
Possible causes:
filter dryer aged, condenser
contaminated
contaminated
4-
Low pressure:
hoch
High pressure:
normal to high
Outflow temperature at the centre vent:
higher depending on bottleneck
Possible causes:
line from condenser to
expansion valve narrowed
expansion valve narrowed
5-
Low pressure:
normal
High pressure:
normal
Outflow temperature at the centre vent:
higher
Possible causes:
too much refrigerant oil in the system