Air conditioning system with orifice tube
Troubleshooting Procedures
parti 2
Outflow temperature at the centre vent :
Low pressure:
normal
parti 2
orifice tube:
Orifice
tubes are used in systems that don’t use expansion valves. Like an
expansion valve, the orifice tube is used to control the amount of
refrigerant entering the evaporator. The diameter of the orifice tube is
similarly small to that of the passage inside the expansion valve, but
there is one big difference between orifice tubes and expansion valves.
An orifice tube is a simple fixed device with no moving parts. It cannot
vary the amount of refrigerant flowing into the evaporator the way an
expansion valve can. So in systems that use orifice tubes, some
additional method of refrigerant flow control must be employed. Two of
the most popular methods used to do this are turning the compressor on
and off at appropriate times, or cycling it, or installing a valve
inside the compressor that can actually cause an adjustment to the
pumping capacity of the compressor. This, of course, regulates the
amount of refrigerant leaving the compressor.
4-
Low pressure:
high
4-
Low pressure:
high
High pressure:
normal
normal
Outflow temperature at the centre vent :
higher
Possible causes:
orifice tube defective (cross-section)
orifice tube defective (cross-section)
5-
Low pressure:
normal
High pressure:
normal
Outflow temperature at the centre vent :
higher
Possible causes:
too much refrigerant oil in the
system
system
6-
Low pressure:
normal to low
normal to low
High pressure:
normal to low
Outflow temperature at the centre vent :
higher
Possible causes:
lack of refrigerant
7-
Low pressure:
low pressure and high pressure are
the same
low pressure and high pressure are
the same
High pressure:
low pressure and high pressure are
the same
the same
Outflow temperature at the centre vent :
ambient temperature
Possible causes:
lack of refrigerant, compressor
defective, fault in the electrical
system
defective, fault in the electrical
system